A structured, annotated report — flagged anomalies with location and severity, temperature-calibrated imagery and measurable maps. Here's the anatomy of a thermal roof survey.
Thermal roof survey
Report № 2026-0412Commercial Warehouse · Worcester, MA
Captured 06 / 2026 · 62,400 ft² · Pilot: Harold Chattaway · FAA Part 1071
Fault
2
Advisories
62.4K
ft² captured
48
hr turnaround
Findings
Fault
Saturated insulation — NE quadrant
Radiometric anomaly consistent with trapped moisture beneath the membrane. Recommend core sample and repair before winter.
Grid C4–C6
Advisory
Sealant degradation at parapet
Cracking observed along the parapet cap flashing on the south elevation. Monitor and re-seal within 12 months.
South parapet
Advisory
Ponding near primary drain
Standing water signature indicates slow drainage. Clear drain and verify slope.
Grid B2
Pass
Membrane field — no defects
Bulk of the roof field reads thermally uniform with no moisture indicators.
Field, all zones